Backflow prevention
Backflow Testing and Repair
A backflow preventer keeps water from irrigation, fire sprinklers, boilers and equipment from flowing back into the drinking water supply. Testing proves it still works.

01Pipes & water lines
Normally water flows one way, from the public main into your building. Backflow happens when that reverses. A drop in main pressure can siphon water backward, and equipment that runs at higher pressure can push water backward. Either way, water from a sprinkler system, boiler or process line can end up in the drinking water.
Backflow preventers stop that with check valves and, in some designs, a relief valve. Common types are the reduced pressure zone assembly, or RPZ, used where the hazard is highest; the double check valve assembly; and the pressure vacuum breaker, often on irrigation systems. Over time, debris and wear keep the valves from sealing, which is why these assemblies are tested with a gauge rather than just looked at.
Many properties have an annual testing requirement set by their water supplier or town. We test, repair and replace backflow assemblies for homes and commercial properties and provide the test documentation.
02When to call
Signs it's time
- 01You received a backflow test notice from your water supplier or town
- 02Your property has irrigation, fire sprinklers, a boiler or commercial equipment
- 03Water discharging from the relief port of an RPZ
- 04An assembly failed its last test
- 05A new system or equipment connection needs a backflow preventer
- 06Assembly is damaged, leaking or froze
03How we handle it
- 1
Identify the assembly
We confirm the type, size and location of each backflow preventer on the property.
- 2
Test with a gauge
We connect a test kit and check that each check valve and relief valve opens and holds at the correct pressures.
- 3
Repair or replace
If it fails, we clean or rebuild the internal parts, or replace the assembly when it cannot be repaired.
- 4
Document
We record the results so you can submit them as your water supplier or town requires.
04What's included
The scope, in plain terms
- Backflow assembly testing and inspections
- Reduced pressure zone (RPZ) testing and service
- Double check valve assembly testing
- Pressure vacuum breaker testing and repair
- Rebuilding failed assemblies
- Replacement of failed or outdated assemblies
- Test documentation and reporting
- Emergency backflow repairs
05Questions
What people ask about backflow testing and repair
Why do I have to test my backflow preventer?
The valves inside can wear or get fouled without any visible sign. A test with a gauge is the only way to know it still protects the water supply. Many water suppliers and towns require it on a schedule, often yearly.
My RPZ is dripping or spraying water. Is it broken?
An RPZ is designed to dump water from its relief port when it detects a problem, so discharge means it is doing its job but something is wrong. Usually a check valve is fouled or worn. It needs service.
What happens if my assembly fails the test?
It needs repair or replacement, then a retest. Often a rebuild with new internal parts is enough. If the body is damaged or the parts are not available, we replace it.
Related work
Backflow Testing and Repair in these towns
- Bloomfield
- Boonton
- Caldwell
- Cedar Grove
- Clifton
- Fairfield
- Franklin Lakes
- Hackensack
- Lincoln Park
- Little Falls
- Livingston
- Madison
- Midland Park
- Montclair
- Montville
- Morristown
- Mountain Lakes
- North Caldwell & West Caldwell
- Nutley
- Oakland
- Paramus
- Parsippany
- Pequannock
- Pompton Plains
- Ridgewood
- South Orange
- Totowa
- Wayne
- West Orange
- Wyckoff
Request service
Tell us what's going on.
We'll get back to you to set a time. Anything urgent, call instead: (973) 513-7751.
